Introduction  
The OMRON MX2 Basic measures your blood pressure and pulse simply and quickly  
from the arm, without the use of an inflation bulb or stethoscope.  
The OMRON MX2 Basic includes a standard cuff for arm circumferences ranging from  
22-32 cm. Optional large cuffs (32-42 cm) can be applied.  
Table of contents  
1 How to obtain meaningful blood  
pressure readings  
2 Overview  
3 Preparation  
4 Operation  
5 Error: causes and rectifications  
6 Maintenance and spare parts  
7 Technical data  
8 General information about blood  
pressure  
7
7
8
1
2
3
4
10  
1 How to obtain meaningful blood pressure readings  
General  
• Avoid eating, drinking (alcohol),  
• The OMRON MX2 Basic is not suitable  
for measuring the frequency of cardiac  
pacemakers.  
• Consult your doctor during pregnancy,  
arrhythmia and arteriosclerosis as this  
can influence the measurement.  
smoking, sport and taking a bath before  
measurement.  
• Be calm and relaxed before and during  
measurement.  
You should never change the dose of  
medicines prescribed by your doctor.  
 
1
MX2 Basic English  
• Store the OMRON MX2 Basic in a dry,  
closed place with a temperature  
between -20°C and 60°C.  
Caution  
• Operating temperature between 10°C  
and 40°C.  
• Remove the batteries if you not intend  
to use the OMRON MX2 Basic for 3  
months or more.  
• Operating environment must be free  
from excessive vibrations, shocks,  
magnetic fields, electrical noise, etc.  
• Stay out of sunlight during measuring.  
• Keep portable phones 5 meters away  
during measurement.  
• Do not wrap the cuff around any object  
other than your arm.  
• Do not fold the cuff and the tube.  
• Do not drop the OMRON MX2 Basic.  
Tips for use  
• Check your blood pressure at least twice  
a day (before breakfast, after work).  
• Do not measure your blood pressure  
while you are in a vehicle.  
• Always measure on the same arm.  
• Wrap the cuff around your arm before  
start of measurement.  
2 Overview  
E
A
S
m
Y
m
S
H
g
M
X
2
B
a
s
i
c
m
D
IA  
m
H
g
P
U
L
S
E
/m  
in  
H
J
D
F
G
B
C
A Display  
B Start button  
C On/off button  
D AC adapter jack  
E Cuff  
F Air tube  
G Air plug  
H Battery  
compartment  
J Air jack  
 
2
MX2 Basic English  
3 Preparation  
Insert batteries  
1 Slide off the battery cover.  
2 Insert four batteries as indicated in the  
battery compartment and close  
compartment  
Caution! Use four identical 1.5V  
batteries type AA!  
Connect cuff  
Fit cuff  
Caution! Do not inflate the cuff when not  
wrapped around the arm!  
B
2
X
M
S
Y
S
g
H
m
m
IA  
D
g
H
m
m
n
i
m
/
E
S
L
U
P
1 Insert air plug in air jack.  
1 Bare your arm.  
Caution! Push up your sleeve: avoid  
constricting the blood flow!  
F Air tube  
K Ring  
K
F
1-2 cm  
2 Pass the end of the cuff through the ring.  
Caution! Keep the air tube on the  
outside!  
3 Put your arm through the loop.  
Note: keep the tube even with your  
middle finger.  
 
3
MX2 Basic English  
1-2 cm  
Note: for right arm use keep the tube  
parallel with your little finger!  
4 Hold the end of the cuff and wrap it  
around your arm.  
Caution! Be sure the cuff fits closely;  
do not pinch your arm!  
4 Operation  
MX2 Basic  
SYS  
mmHg  
L
M
DIA  
mmHg  
PULSE/min  
S
R
C
B
N
P
Q
Control functions  
B Start button  
C On/off button  
N Diastolic blood pressure in mmHg.  
P Pulse: heartbeats per minute.  
Q Battery exhausted: batteries are  
weak/exhausted.  
Measurement  
R Deflation: cuff deflates and  
measurement finishes.  
S Inflation: cuff inflates and measurement  
L Systolic blood pressure in mmHg.  
M Heart symbol: flash - measurement  
takes place, light up - finish  
measurement.  
starts.  
 
4
MX2 Basic English  
Caution! Allow an interval of at least three minutes between two successive measurements!  
1 Sit comfortably at a table with your feet  
flat on the floor and rest your arm on  
the table.  
2 Relax your arm and turn your palm  
upward.  
Caution! Cuff at heart height during  
measurement!  
MX2 Basic  
MX2 Basic  
MX2 Basic  
SYS  
mmHg  
SYS  
mmHg  
SYS  
mmHg  
DIA  
mmHg  
DIA  
mmHg  
DIA  
mmHg  
PULSE/min  
PULSE/min  
PULSE/min  
3 Press on/off button.  
Caution! Wait for zero and the heart symbol to continue!  
MX2 Basic  
SYS  
mmHg  
DIA  
mmHg  
PULSE/min  
4 Press start button  
Note: press and hold the start button to  
set pressure higher than 170 mmHg.  
Caution! Do not inflate over 280  
mmHg!  
Note: the unit inflates the cuff to 170  
mmHg. If required the unit  
automatically increases the pressure by  
40 mmHg.  
 
5
MX2 Basic English  
MX2 Basic  
MX2 Basic  
MX2 Basic  
SYS  
mmHg  
SYS  
mmHg  
SYS  
mmHg  
DIA  
mmHg  
DIA  
mmHg  
DIA  
mmHg  
PULSE/min  
PULSE/min  
PULSE/min  
Note: the cuff deflates automatically.  
Caution! Sit still, do not move and do not  
speak!  
Read display  
MX2 Basic  
MX2 Basic  
SYS  
mmHg  
SYS  
mmHg  
DIA  
mmHg  
DIA  
mmHg  
PULSE/min  
PULSE/min  
1 Read the values of blood pressure and pulse from the display.  
Note: display shows blood pressures and heartbeats alternately.  
MX2 Basic  
SYS  
mmHg  
DIA  
mmHg  
PULSE/min  
2 Note values in your personal blood  
pressure pass.  
3 Press on/off button to turn off power.  
Note: power automatically shuts off in 5  
minutes.  
 
6
MX2 Basic English  
5 Error: causes and rectifications  
Indication  
Error  
Cause  
Rectification  
Correct  
reading  
not  
Cuff pressure  
low  
Wait for at least three minutes to repeat  
measurement.  
Inflate the cuff 40 mmHg higher than  
previous value.  
possible  
Movement  
Follow instructions, repeat  
measurement.  
Very weak  
artery pulse  
Cuff pressure  
too high  
Wait for at least three minutes to repeat  
measurement.  
Inflate the cuff 30 mmHg lower than  
previous value.  
Follow instructions, repeat  
measurement.  
Low  
Batteries weak/ Fit four new identical 1.5V  
voltage  
exhausted  
batteries type AA  
Display empty  
6 Maintenance and spare parts  
• Use a soft, slightly moistened cloth to  
clean the OMRON MX2 Basic.  
Caution! Do not use petrol, thinners or  
similar solvents!  
• Use a soft, moistened cloth and soap to  
clean the cuff.  
Caution! Do not wash the cuff!  
Caution! Do not use petrol, thinners or  
similar solvents!  
OMRON retail outlet or distributor as  
mentioned on the packaging.  
Calibration  
• It is recommended to have the OMRON  
MX2 Basic inspected every two years to  
ensure correct function and accuracy.  
Consult your OMRON retail outlet or  
OMRON distributor as mentioned on the  
packaging.  
• Do not carry out repairs of any kind  
yourself. If a defect occurs consult your  
Replace batteries  
• Remove the battery out of the battery  
 
7
MX2 Basic English  
compartment and insert four new identical  
1.5V batteries type AA.  
Spare parts  
• Due to high company quality standards,  
OMRON considers the main unit as a  
non-serviceable part because the need  
for proper calibration after replacement  
of high tech components.  
Attention! Disposal of batteries and the  
OMRON MX2 Basic should be  
carried out in accordance with  
the national regulations for the  
disposal of electronic products.  
7 Technical data  
Product name  
Model  
Display  
OMRON Digital Automatic Blood Pressure Monitor  
MX2 Basic  
Digital LCD  
Measurement range  
Accuracy  
Pressure: 0 - 299 mmHg / Pulse: 40 - 180 / minute  
Pressure: 3 mmHg  
Pulse: 5% of display reading  
Automatic by electric pump  
Inflation  
Deflation  
Automatic pressure release valve  
Automatic exhaust valve  
Capacitive pressure sensor  
Oscillometric method  
4 x 1.5V batteries type AA  
Rapid pressure release  
Pressure detection  
Measurement method  
Power supply  
AC adapter (optional part)  
Battery life  
New batteries will last for approximately 300 measurements  
Operating temperature/humidity +10°C to +40°C / 30% to max. 85% relative humidity  
Operating environment  
Free from excessive vibrations, shocks, magnetic fields,  
electrical noise, etc.  
Storage temperature/humidity  
Weight  
Outer dimensions  
Cuff dimensions  
Arm circumference  
Accessories  
-20°C to +60°C /10% to max. 95% relative humidity  
Approximately 350 g including cuff, excluding batteries  
Approximately 118 mm (W) x 90 mm (H) x 130 mm (D)  
Approximately 145 mm (W) x 480 mm (L)  
22 cm to 32 cm  
Cuff, instruction manual, guarantee card, blood pressure pass  
Large cuff for arm circumferences between 32 - 42 cm, AC adapter  
Subject to technical modification without prior notice  
Optional parts  
Note  
= Type B  
Manufacturer  
OMRON HEALTHCARE Co., Ltd.  
24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto, 615-0084 Japan  
EU-representative  
OMRON HEALTHCARE EUROPE B.V.  
Kruisweg 577, NL-2132 NA Hoofddorp  
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood  
pressure monitor is designed according to the European standard EN1060, Non-invasive  
sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for  
electromechanical blood pressure measuring systems.  
 
8
MX2 Basic English  
Important information regarding Electro Magnetic Compatibility (EMC)  
With the increased number of electronic devices such as PC.s and mobile (cellular) telephones,  
medical devices in use may be susceptible to electromagnetic interference from other devices.  
Electromagnetic interference may result in incorrect operation of the medical device and create a  
potentially unsafe situation.  
Medical devices should also not interfere with other devices.  
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to  
prevent unsafe product situations, the EN60601-1-2 standard has been implemented. This  
standard defines the levels of immunity to electromagnetic interferences as well as maximum  
levels of electromagnetic emissions for medical devices.  
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2001  
standard for both immunity and emissions.  
Nevertheless, special precautions need to be observed:  
• Do not use mobile (cellular) telephones and other devices, which generate strong electrical or  
electromagnetic fields, near the medical device. This may result in incorrect operation of the unit  
and create a potentially unsafe situation. Recommendation is to keep a minimum distance of  
7 m. Verify correct operation of the device in case the distance is shorter.  
Further documentation in accordance with EN60601-1-2:2001 is available at OMRON Healthcare  
Europe at the address mentioned in this instruction manual.  
Correct Disposal of This Product  
(Waste Electrical & Electronic Equipment)  
This marking shown on the product or its literature, indicates that it should not be  
disposed of, with other household wastes at the end of its working life. To prevent  
possible harm to the environment or human health from uncontrolled waste disposal,  
please separate this from other types of wastes and recycle it responsibly to promote the  
sustainable reuse of material resources.  
Household users should contact either the retailer where they purchased this product, or their  
local government office, for details of where and how they can take this item for environmentally  
safe recycling.  
Business users should contact their supplier and check the terms and conditions of the purchase  
contract. This product should not be mixed with other commercial wastes for disposal.  
This product does not contain any hazardous substances.  
 
9
MX2 Basic English  
8 General information about blood pressure  
Blood circulation  
Health and blood pressure  
The blood circulation is responsible for  
supplying the body with oxygen. Blood  
pressure is the pressure exerted on the  
arteries.  
The systolic blood pressure value (higher  
pressure or top value) represents the  
The incidence of hypertension increases  
with age. In addition, a lack of exercise,  
excess body fat and high levels of choles-  
terol (LDL), which sticks to the inside in  
blood vessels, reduces elasticity of these  
vessels. Hypertension accelerates arterial  
blood pressure produced by contraction of sclerosis which can lead to very serious  
the heart muscle.  
conditions such as stroke and myocardial  
infarction. For these reasons it is very  
important to know whether the blood  
pressure is within a healthy range. Blood  
pressure fluctuates from minute to minute,  
throughout the day. Therefore it is essential  
to take regular measurements to help you  
identify an average blood pressure.  
The diastolic blood pressure value (lower  
pressure or lower value) represents the  
blood pressure produced by relaxation of  
the heart muscle.  
Classification of blood pressure  
The World Health Organisation (WHO)  
and the International Society of  
Hypertension (ISH) developed the blood  
pressure classification. This classification  
is based on the blood pressure values  
measured while sitting on a chair in the  
outpatient department of a hospital.  
Symptoms of high blood pressure  
High blood pressure can go unnoticed for  
a long time, since it does not cause notice-  
able symptoms. The following are all  
possible causes of abnormally high blood  
pressure:  
Systolic blood pressure  
(mmHg)  
Severe hypertension  
180  
Moderate hypertension  
Mild hypertension  
Normal systolic value  
160  
140  
130  
120  
Normal blood  
pressure  
Optimal blood  
pressure  
(target value)  
Diastolic  
blood  
pressure  
(mmHg)  
80  
85  
90  
100 110  
According to the blood pressure classification by the WHO/ISH.  
 
10  
MX2 Basic English  
• Overweight  
• High cholesterol level  
• Smoking  
• Excessive alcohol consumption  
• Stress and emotional upset  
• Excessive consumption of salt  
• Lack of physical exercise  
• Genetic/hereditary predisposition  
• Underlying illnesses, such as kidney  
disorders or endocrine disturbance  
tension may cause your blood pressure to  
be higher than in familiar circumstances at  
home. This is known as “White Coat  
Hypertension”.  
Treatment of high blood pressure  
If your blood pressure reaches upper  
values of 140 - 160 mmHg and lower  
values of 90 - 95 mmHg in repeated  
measurements over several days, you  
should consult your doctor for detailed  
medical examination. You can assist the  
treatment prescribed by your doctor in the  
following ways:  
• Loose weight and lower your cholesterol  
level by reducing the calories and fat in  
your diet. Cut down on animal fats and  
eat more fruit and vegetables.  
• Reduce the consumption of alcohol.  
• Reduce the intake of salt: the German  
League for Combating High Blood  
Pressure recommends six grams of salt  
per day (i.e. one teaspoon) on average.  
• Stop smoking.  
Blood pressure measurement  
Measuring your blood pressure daily  
enables you to recognize high blood  
pressure at an early stage and obtain  
medical treatment.  
The oscillometric method of measurement  
determines your blood pressure by  
measuring the pressure fluctuations  
caused by the pulse waves.  
Since your blood pressure fluctuates  
within a day (see graphic next page), you  
should always measure it at the same  
time each day to ensure that the  
measurements are genuinely comparable. Take regular exercise.  
At the doctor’s surgery, nervousness and  
• Monitor your blood pressure.  
Upper curve: systolic blood pressure  
Lower curve: diastolic blood pressure  
200  
150  
100  
50  
6
12  
18  
24  
Time of day  
Example: fluctuation within a day (male, 35 years old)  
 
11  
MX2 Basic English  
OMRON HEALTHCARE CO., LTD.  
24, Yamanouchi Yamanoshita-cho, Ukyo-ku,  
Kyoto, 615-0084 Japan  
Manufacturer  
OMRON HEALTHCARE EUROPE B.V.  
Kruisweg 577, 2132 NA Hoofddorp,  
The Netherlands  
EU-representative  
Production Facility  
EC  
REP  
OMRON DALIAN CO., LTD.  
Economic & Technical Development Zone  
Dalian 116600, China  
OMRON HEALTHCARE UK LTD.  
Opal Drive  
Fox Milne, Milton Keynes MK15 0DG, United Kingdom  
OMRON Medizintechnik Handelsgesellschaft mbH  
John-Deere-Str. 81a, 68163 Mannheim, Germany  
Subsidiary  
OMRON SANTÉ FRANCE SAS  
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France  
Made in China  
 
12  

Milwaukee Drill 490 16200 User Manual
Moulinex Toaster Isilys Express User Manual
MTD Tiller 192 766 User Manual
Nady Systems Headphones Digital Sound Level Meter DSM 1 User Manual
National Instruments Switch PCI PXI 783xR User Manual
NEC Projector NP V281W User Manual
Nikon Camera Accessories WR A10 User Manual
Oki Printer C8600 User Manual
Optoma Technology Projector EP705H User Manual
Panasonic Conference Phone KX T7230 User Manual